THERMOGARD™ WHITE POLYIMIDE LABEL STOCK 
Technical
Data Sheet
POLYONICS,
INC.
POLYONICS
XF-541 THERMAL TRANSFER PRINTABLE POLYIMIDE LABEL STOCK
Description:
Polyonics XF-541 is a polyimide label material with a permanent
pressure sensitive acrylic adhesive and a high opacity,
matte tan topcoat specifically designed for thermal transfer
printing on polyimide labels.
Polyonics
XF-541 polyimide label material is designed for barcode or alphanumeric
identification of printed circuit boards, or related electronic
components. It is the ideal label to withstand mixed circuit board
processes, on either the top or bottom side of the board. It has
excellent resistance to harsh fluxes, cleaners, saponifiers, and
wave solder environments, and resists all commonly employed methods
of cleaning. XF 541 polyimide labels are one of several polyimide
label materials available.Click on POLYIMIDE
LABELS.
The
printed polyimide label resists smearing, even when the board and
label are directly removed from a reflow or wave solder environment.
The XF-541 matte topcoat resists solder balls. For a list of recommended
thermal transfer ribbons see Thermal
Ribbons for Polyimide Labels.
XF-541 polyimide label material can also be printed with dot matrix,
laser, and ink jet printing technologies. Please email Printing
on Polyimide Labels Help, for more information.
The
choice of thermal transfer printer can make a real difference as
well on the overall polyimide label performance. Our materials can
be used with most industrial thermal transfer printers, such as
Zebra, Intermec, Sato, Printronix, NEC, Datamax, and Brady label
printers, for harsh environment bar code label printing with a wide
variety of thermal transfer ribbons.
XF-541
polyimide labels are also suitable for use in ISO clean-room applications,
when used with a film liner instead of a paper liner. Contact Polyimide
Labels for Clean Rooms for further information.
For
additional literature or FREE SAMPLES
please visit Polyimide
and Kapton Label Samples and Literature.
Test data and test results contained
in this document are for general information only and shall not
be relied upon by Polyonics customers for designs and specifications,
or be relied on as meeting specified performance criteria. All values
shown are averages and should not be used for specification Purposes.
Customers desiring to develop specifications or performance criteria
for specific product applications should contact Polyonics for further
information.
Some
useful properties of XF 541 printable white polyimide label material
| Property |
Method |
Result |
| Adhesive
thickness |
ASTM
D 1000 |
0.0018-.0020
in.(0 .046-0.051 mm) |
| 180
degree Peel Adhesion |
ASTM
D 1000 |
24 hour dwell 35 oz/in (39 N/100 mm) |
| 72
hour dwell 50 oz/in (55 N/100 mm) |
| Flammability |
ASTM
D 1000 |
Average
Burn Time< 2 seconds |
| Coated
film thickness |
ASTM
D 1000 |
0.0024-.0027
in.(0.061-0.069 mm) |
| Dielectric
Strength |
ASTM
D 1000 |
>
8 kv |
THERMAL CHARACTERISTICS
| PERFORMANCE
PROPERTIES |
TYPICAL RESULTS |
| Short
Term High Service |
Temperature
5 minutes at 500°F (260°C)
300°C label moderately discolors.
Label remains functional. |
| 2
hours at 338°F (170°C) |
No
visible effect to label at 170°C,
Label discolors at 190°C
Moderately at 220°C
Severely at 260°C.
Label remains functional. |
| Long
Term High Service Temperature |
1000
hours at 212°F (100°C)
No visible effect to label at 100°C
Label discolors slightly at 120°C
Moderately at 145°C.
Label remains functional. |
Chemical
Resistance, measured by PCS (Print Contrast Signal)
| CHEMICAL |
TEST
CONDITION |
PCS |
| Control |
Heat
, 5 minutes |
99
% |
| Trichloroethane |
74°C,
10 minutes |
98
% |
| Aquanox
SSA 30% aqueous |
40-50°C,
10 minutes |
98% |
| RE-ENTRY®
KNI 2000 Terpene |
40-50°C,
10 minutes |
98% |
| BIOACT®
EC-7R Terpene |
40-45°C,
10 minutes |
98% |
Alpha Metals Inc. 2110 Saponifier 6% aqueous |
65-70°C,
10 minutes |
98% |
| Isopropanol
99% |
82°C,
10 minutes |
99% |
| Deionized
Water |
100°C,
10 minutes |
99% |
Customer
experience, supported by our laboratory data clearly show that XF
541 polyimide label material can be stored for at least one year
in an environment below 80 degrees F and 60% RH . We are confident
that our product will perform well beyond this time frame. However,
it remains the responsibility of the user to assess the risk of
using such product. We encourage customers to develop functional
testing protocols that will qualify a product's fitness for use,
in their actual applications.
Aquanox
SSA„® is a trademark of Kyzen Corporation. BIOACT®
is a registered trademark of Petroferm, Inc.
EC-7® is a trademark of Petroferm Inc. Fluorinert„®
is a trademark of the 3M Corporation RE-ENTRY® is a registered
trademark of Environsolv Inc.
WARRANTY
Polyonics products are sold with the understanding
that the buyers will test them in actual use and determine for themselves
their adaptability to their intended uses. Polyonics warrants to
the buyers that its products are free from defects in material and
workmanship, but limits its obligation under this warranty to replacement
of the product shown to Polyonics' satisfaction to have been defective
at the time Polyonics sold it. This warranty does not extend to
any persons obtaining the product from the buyers. This warranty
is in lieu of any other warranty, express or implied, including,
but not limited to, any implied warranty of merchantability or fitness
for a particular purpose, and of any other obligations or liability
on Polyonics' part. Under no circumstances will Polyonics be liable
for any loss, damage, expense, or consequential damages of any kind
arising in connection with the use, or inability to use, Polyonics'
products.
|