THERMOGARD™ WHITE POLYIMIDE LABEL STOCK
Technical
Data Sheet
For
lead free applications
POLYONICS,
INC.
POLYONICS
XF-584 THERMAL TRANSFER PRINTABLE WHITE POLYIMIDE LABEL STOCK
Description:
Polyonics XF-584 is a polyimide label material coated with a permanent
pressure sensitive acrylic adhesive and a high opacity, matte white
topcoat specifically designed for thermal transfer printing.
Polyonics
XF-584 polyimide label material is designed for barcode or alphanumeric
identification of
printed circuit boards, or related electronic components. It is
the ideal polyimide label to withstand mixed circuit board processes,
on either the top or bottom side of the board. It has excellent
resistance to harsh fluxes, cleaners, saponifiers, and wave solder
environments, and resists all commonly employed methods of cleaning.
XF 584 polyimide labels are one of several polyimide label materials
available. Click on Polyimide
Label Products.
When used with the proper ribbon, XF 584 polyimide labels pass MIL-STD-202F
method 215J. The
printed polyimide label resists smearing, even when the board and
label are directly removed from
a reflow or wave solder environment. For a list of recommended thermal
transfer ribbons see
Thermal
Transfer Ribbons for Polyimide Labels .
Colored versions of XF-584 polyimide label material are available.
To see more details click on Custom
Colored Polyimide Labels.
The
choice of thermal transfer printer can make a real difference as
well on the overall polyimide label performance. Our materials can
be used with most industrial thermal transfer printers, such as
Zebra, Intermec, Sato, Printronix, NEC, Datamax, and Brady label
printers, for harsh environment bar code label printing with a wide
variety of thermal transfer ribbons.
XF-584
polyimide labels are also suitable for use in ISO clean-room applications,
when used with a film liner instead of a paper liner. Contact Polyimide
Label Materials for Clean Rooms for further information.
For
additional literature or FREE SAMPLES please visit Polyimide
Label Samples and Literature.
Test
data and test results contained in this document are for general
information only and shall not be relied upon by Polyonics customers
for designs and specifications, or be relied on as meeting specified
performance criteria. All values shown are averages and should not
be used for specification Purposes. Customers desiring to develop
specifications or performance criteria for specific product applications
should contact Polyonics for further information.
Some
useful properties of XF 584 printable white polyimide label material:
| Adhesive
thickness |
ASTM
D 1000 |
0.0018-.0020
in.(0 .046-0.051 mm) |
| 180
degree peel adhesion |
ASTM
D 1000 |
24 hour dwell 35 oz/in (39 N/100 mm) |
| 72
hour dwell 50 oz/in (55 N/100 mm) |
| Coated
film thickness |
ASTM
D 1000 |
0.0024-.0027
in.(0.061-0.069 mm) |
| Flammability |
ASTM
D 1000 |
Average
Burn Time< 2 seconds |
| Dielectric
Strength |
ASTM
D 1000 |
>
8 kv |
Thermal
performance characteristics are listed below.
| PERFORMANCE
PROPERTIES |
TYPICAL
RESULTS |
|
Short Term High Service Temperature |
50
minutes at 600°F (315 °C)
No visible effect
(See
for yourself ........Lead
Free Polyimide Labels)
Label remains functional. |
| 2
hours at 338°F (170°C) |
No
visible effect to label at 170°C,
190°C, or 220°C
Label remains functional. |
| Long
Term High Service Temperature |
1000
hours at 212°F (100°C)
No visible effect to label at 120°C
label discolors slightly at 145°C
Label remains functional. |
Thermal
Transfer Ribbons which can be successfully used with XF 584**
| Manufacturer |
Ribbon |
UL |
| ARMOR |
AXR8+ |
|
| Coding
Products/ITW |
7993 |
|
| Dai
Nippon |
R
510 |
†† |
| Japan
Pulp and Paper |
JP1 |
†† |
| Mid-City
Columbia |
MML-23HE |
|
| Ricoh |
110C |
†† |
| SONY
Chemical |
Signature
Series |
|
| 4070 |
|
| TXR75 |
†† |
| Union
Chemicar |
US300
|
†† |
See
also UL recognition details of XF 584, at UL
Polyimide Labels.
Chemical
Resistance, measured by PCS (Print Contrast Signal):
| CHEMICAL |
TEST
CONDITION |
PCS |
| Control |
260°C
heat, 5 minutes |
99% |
| Trichloroethane,
|
74°C,
10 minutes |
98% |
| Aquanox
SSA 30% aqueous, |
40-50°C,
10 minutes |
98% |
| RE-ENTRY®
KNI 2000 Terpene |
40-50°C,
10 minutes |
98% |
| BIOACT®
EC-7R Terpene |
40-45°C, 10 minutes |
98% |
| Alpha
Metals Inc. 2110 Saponifier |
|
|
6% aqueous |
65-70°C,
10 minutes |
98% |
| Isopropanol
99%, |
82°C,
10 minutes |
99% |
| Deionized
Water, |
100°C,
10 minutes |
99% |
Customer
expectations, supported by our laboratory data clearly show that
XF 584 polyimide label material can be stored for at least one year
in an environment below 80 degrees F and 60% RH . We are confident
that our product will perform well beyond this time frame. However,
it remains the responsibility of the user to assess the risk of
using such product. We encourage customers to
develop functional testing protocols that will qualify a product's
fitness for use, in their actual applications.
Aquanox
SSA® is a trademark of Kyzen Corporation. BIOACT® is a registered
trademark of Petroferm, Inc.
EC-7® is a trademark of Petroferm Inc. Fluorinert„®
is a trademark of the 3M Corporation RE-ENTRY® is a registered
trademark of Environsolv Inc.
INK
RIBBONS DISCLAIMER NOTE:
Polyonics, Inc., does not sell or endorse ribbons from specific
ribbon companies. Our recommendations are based solely on Polyonics’
testing methods and procedures and are subject to revision without
further notice.
WARRANTY
Polyonics products are sold with the understanding that the buyers
will test them in actual use and determine for themselves their
adaptability to their intended uses. Polyonics warrants to the buyers
that its products are free from defects in material and workmanship,
but limits its obligation under this warranty to replacement of
the product shown to Polyonics' satisfaction to have been defective
at the time Polyonics sold it. This warranty does not extend to
any persons obtaining the product from the buyers. This warranty
is in lieu of any other warranty, express or implied, including,
but not limited to, any implied warranty of merchantability or fitness
for a particular purpose, and of any other obligations or liability
on Polyonics' part. Under no circumstances will Polyonics be liable
for any loss, damage, expense, or consequential damages of any kind
arising in connection with the use, or inability to use, Polyonics'
products.
|